Aortic Dissection Detection Risk Score (ADD-RS) with D-dimer (ADvISED)

Current versionCardiac·13 inputs·3 references

Based on Isselbacher EM et al. (2022).

Built from the primary publication cited below. Pogosh CDS is built by Pouyan Golshani, MD, interventional radiologist. Page last reviewed October 11, 2026.

Decision support for clinicians — review before acting.

ng/mL
Runs only when you press Calculate. Values are not stored.

How it is calculated

Twelve markers sit in 3 categories: high-risk conditions (such as Marfan syndrome or known thoracic aortic aneurysm), high-risk pain (abrupt, severe, or ripping or tearing) and high-risk exam findings (such as pulse deficit or shock). Each category with at least 1 marker scores 1 point, for a total of 0 to 3. A D-dimer in ng/mL is optional; below 500 counts as negative.

How to read the result

0 is low, 1 is moderate and 2–3 is high pretest risk. In ADvISED (n = 1850), a score of 1 or less with D-dimer below 500 ng/mL ruled out acute aortic syndrome with a failure rate of 0.3%. With a D-dimer of 500 ng/mL or more it is not excluded. The D-dimer rule-out was evaluated only for scores of 1 or less, so it does not apply at 2 or 3.

References

  1. Isselbacher EM, Preventza O, Hamilton Black J 3rd, et al. 2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease. Circulation. 2022;146:e334-e482. PMID 36322642; PMC9876736 (Table 24, adapted from Hiratzka 2010). PubMed 36322642
  2. Rogers AM, Hermann LK, Booher AM, et al. Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the International Registry of Acute Aortic Dissection. Circulation. 2011;123:2213-2218. PMID 21555704. PubMed 21555704
  3. Nazerian P, Mueller C, Soeiro AM, et al. Diagnostic accuracy of the aortic dissection detection risk score plus D-dimer for acute aortic syndromes: the ADvISED prospective multicenter study. Circulation. 2018;137:250-258. PMID 29030346. PubMed 29030346
Implementation notes

D-dimer units must be ng/mL in the assay's own reporting basis as used in ADvISED; the abstract does not state FEU vs DDU.