How it is calculated
Oxygen content (mL/dL) = 1.34 × hemoglobin × saturation / 100 + 0.0031 × PO2, calculated for arterial and for mixed venous blood. Cardiac output (L/min) = oxygen consumption (mL/min) / ((CaO2 − CvO2) × 10). If body surface area is entered, cardiac index (L/min/m²) = cardiac output / body surface area.
How to read the result
Normal cardiac index is about 2.5–4.0 L/min/m². An assumed oxygen consumption (about 125 mL/min/m²) is the largest source of error; in critical illness the real value can differ widely. If venous content is not below arterial content, no output is given and the sample labels need checking.