Mean arterial pressure (MAP)
Estimates mean arterial pressure from a cuff reading as (SBP + 2 × DBP) / 3, with an optional heart-rate-corrected estimate because the standard formula underestimates MAP at faster heart rates..
Built from the primary publication cited below. Pogosh CDS is built by Pouyan Golshani, MD, interventional radiologist. Page last reviewed October 11, 2026.
Decision support for clinicians — review before acting.
How it is calculated
MAP = (systolic + 2 × diastolic) / 3, in mmHg. Pulse pressure = systolic − diastolic. If heart rate is entered, a heart-rate-corrected estimate is also given: MAP = diastolic + (0.33 + 0.0012 × heart rate) × pulse pressure.
How to read the result
The standard formula estimates the mean pressure over one cardiac cycle. It assumes diastole lasts two-thirds of the cycle, so it reads lower than the true mean as heart rate rises. An arterial line measures MAP directly. For reference, the Sepsis-3 definition of septic shock includes needing vasopressors to keep MAP at 65 mmHg or higher.
References
- Razminia M, Trivedi A, Molnar J, et al. Validation of a new formula for mean arterial pressure calculation: the new formula is superior to the standard formula. Catheter Cardiovasc Interv. 2004;63:419-425. PMID 15558774. PubMed 15558774
- Rogers G, Oosthuyse T. A comparison of the indirect estimate of mean arterial pressure calculated by the conventional equation and calculated to compensate for a change in heart rate. Int J Sports Med. 2000;21:90-95. PMID 10727067. PubMed 10727067
- Singer M, Deutschman CS, Seymour CW, et al. The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). JAMA. 2016;315:801-810. PMID 26903338; PMC4968574. PubMed 26903338
Implementation notes
The corrected formula was derived from central-aortic pressures and validated at paced heart rates in 12 patients, so it is shown for information only.
In Pogosh, this calculator is suggested when a note mentions septic shock, cardiogenic shock. See it on a sample case (free, no account).
Pogosh CDS reads a clinical note and returns the labs, imaging, routing and the calculators that fit. Run a sample case (free, no account), browse all calculators, or call them through the API.